Switch 38

38

Upper Left Loop

Matrix column 3, row 8 ·  

Wiring

Column 3
Green-Orange J206-3 · U20-16
Row 8
White-Grey J208-9 · U19-7

Parts

Location

Owner's hint
Rollover switch with a wire actuator. Check that the wire moves freely and the microswitch clicks. (owner's experience, not the manual)

Related

Service log

 

Everything you record stays on this device.

Service notes: In the switch matrix at column 3 (J206-3, U20-16) and row 8 (J208-9, U19-7). Gap 1/16 inch; clean by pulling card stock through the closed contacts, never a file. One switch that fails T.1 is its gap, the wire at the lug or its diode; a shorted diode makes the whole column or row misread. A whole column dead is U20 or the J206 pin, a whole row is the row comparator. A3 Switches and optos