Plumb Bob Tilt
Matrix column 1, row 4 ·
Wiring
- Column 1
- Green-Brown J206-1 · U20-18
- Row 4
- White-Yellow J208-4 · U18-7
Parts
- Assembly 20-6502-A
Location
- Not on the playfield map: on the coin door or in the cabinet.
- Not shown on the location map
Owner's hint
Coin door / cabinet switch. Dedicated or matrix according to the table. (owner's experience, not the manual)
Service log
Everything you record stays on this device.
Service notes: In the switch matrix at column 1 (J206-1, U20-18) and row 4 (J208-4, U18-7). Gap 1/16 inch; clean by pulling card stock through the closed contacts, never a file. One switch that fails T.1 is its gap, the wire at the lug or its diode; a shorted diode makes the whole column or row misread. A whole column dead is U20 or the J206 pin, a whole row is the row comparator. A3 Switches and optos