Solenoid 13

SOL 13

Lower Jet

Low Power ·  

Wiring

Wire
Brown-Green J127-6 · Q50
Fuse
F104 (3A S.B.) (derived from the fuse list, not printed per coil)

Parts

Location

Related

Service log

 

Everything you record stays on this device.

Service notes: Measure across the two lugs, game off: about 10.5–10.8 Ω (vendor). Near 0 Ω is a shorted coil that blows fuse F104 (3A S.B.); open is a dead coil. Then the diode across the lugs, the driver transistor Q50 on the driver board, and the connector pin J127-6. A coil that locks on is the transistor, not the coil. Never oil the plunger or the sleeve. A2 Coils, magnets and motors